Signature generation status register
RESERVED | Reserved. The value read from a reserved bit is not defined. |
SIG_DONE | When 1, a previously started signature generation has completed. See FMSTATCLR register description for clearing this flag. |
RESERVED | Reserved. The value read from a reserved bit is not defined. |
END_OF_RDWR | EEPROM read/write operation finished interrupt status bit. Bit is: - set when this operation has finished OR when 1 is written in the corresponding bit of the EEINTSTATSET register. - cleared when 1 is written to the corresponding bit of the EEINTSTATCLR register. |
RESERVED | Reserved. The value read from a reserved bit is not defined. |
END_OF_PROG1 | EEPROM program operation finished interrupt status bit. Bit is: - set when this operation has finished OR when 1 is written to the corresponding bit of the EEINTSTATSET register. - cleared when 1 is written to the corresponding bit of the EEINTSTATCLR register. |
RESERVED | Reserved. The value read from a reserved bit is not defined. |